Skip to content

Coating simulator

The coating you will get, before the rectifier is on.

Change one parameter and see the effect on the coating: thickness, voltage, heat in the bath and hardness. After the load, compare the calculation with what the gauge showed on the part.

What it does

Record the load from the simulator, measure the coating and see the deviation. 159 aluminium alloys in the simulator.

  • 01 / 04

    Cell simulation

    Constant current or voltage, time, free acid, dissolved aluminium, temperature, additive, area, anode–cathode distance, busbars and contacts.

  • 02 / 04

    159 alloys

    A conductivity table with 159 alloys in 23 anodizing-response families. The alloy shifts the voltage threshold, film resistance and efficiency.

  • 03 / 04

    Heat and cooling

    Power dissipated in the bath, heating over the load and chiller capacity. The simulator warns when a load is heading towards burning.

  • 04 / 04

    Comparator

    Measured thickness against calculated thickness, load by load. The calculation does not adjust to the measurements: the gap points to the bath and the installation.

On the line, day to day

  1. Pick the alloy and the mode: constant current or constant voltage.
  2. Enter the bath (acid, aluminium, temperature) and the load (area, time).
  3. Read the thickness, coating class, voltage and alerts.
  4. After the load, log the measured thickness in the Comparator.
Example

Alloy 6063, sulphuric anodizing, constant current

Current density
1.5 A/dm²
Time
40 min
Bath
190 g/L H₂SO₄ · 8 g/L Al
At 20 °C
17.8 µm · 16.8 V · 300 HV
At 24 °C
16.0 µm · 15.1 V · 260 HV

Model labchemi-model-1.2. In a warmer bath more oxide dissolves in the acid: the coating comes out thinner and softer with the same current and time.

Questions

Coating simulator

Does the simulator replace the test panel?

No. It estimates trends from a model. Test-panel trials and analytical bath control are still needed.

Why doesn’t the calculation learn from my measurements?

On purpose. If the calculation made up the difference, an out-of-range bath would hide behind a corrected number. With a fixed calculation, the gap in the Comparator points to the cause.

Does it work for hard anodizing?

Yes. There is a starting point for hard coating, with a cold bath and high current, and the simulator tracks the heat and the risk of burning.

Platform

Other areas of Labchemi

Start with your line.

Create your company account, register your baths and log the first analysis. In the browser, nothing to install.