Skip to content

Anodizing line control system

Your industry in the age of AI.

A calculated correction for every bath. A reorder date for every chemical. Coating thickness predicted before every load.

Knowledge network

Be part of the network that moves the aluminium market.

The network's knowledge comes from studies and tests published by partners and from articles chosen by Labchemi's own curation.

57
institutions on the map
18
countries
6
fronts, from chemistry to research
Chemicals and dyes
Germany
  • LABCHEMI · BRAZIL
  • LABCHEMI · EUROPE
Drag to rotate
04 / 57

Each point is an institution that cooperates with the network, linked to Labchemi's nearest office.

Simulator

Try the simulator.

The same model as the Simulator inside the platform. Set the rectifier voltage and the bath time and simulate the load.

Alloy 6063-T5 · H₂SO₄ 190 g/L · 20 °C · black

Theoretical model of the cell. The images are scale drawings of what was calculated, not photographs. The full simulator adds the alloy, bath, temperature, dye and rectifier.

Use the full simulator
Target 15–20 µm
16.2µm

Loading the simulator…

40 min load
Coating
Part
Pores
Current density—A/dm²
Microhardness—HV
Growth rate—µm/min

How it works

We set up your line in the system with you.

Each tank keeps its own analyses, with the working range beside every value. Click a tank to see its history.

Example parameters and analyses.

Line and baths

The line in 3D, tank by tank.

The health of each bath in its place on the line. Set up stages, volumes and the range of every parameter.

Drag to rotate · click a tank

Anodizing line in perspective, with the baths lit
Demo line

Comparator

A large deviation points to the bath, not to the maths.

Theoretical18.0µm
Measured17.8µm
Deviation-1.0%
051015200 min10 min20 min30 min40 minCOATING (µm)T4 · ANODIZINGOut of range · H₂SO₄ 162 g/LWorking range 180 to 200 g/L. Correct it before the next load.
01Simulate

Enter the voltage and the bath time. The simulator returns the coating thickness.

02Produce

The load runs on the line. What comes out of the tank is the measured result.

03Measure

Record the measured coating. The Comparator puts measured and theoretical side by side.

04Correct the bath

The simulator does not calibrate itself with the measurement. You correct the bath, and the next load goes back to the theoretical line.

Commitments

Four commitments, each with proof in the product.

The person decides

The assistant prepares the entry. It is only saved when someone confirms it on screen. Stock withdrawals are always manual.

The deviation is the signal

The simulator does not calibrate itself with line data. Measured is compared with theoretical, and the difference points to the bath.

Every number has a source

Every limit keeps its source and nature: standard, supplier data sheet, rule of thumb or derivation.

The data belongs to the customer

One isolated account per company, full export and account deletion. The platform sees numbers, never names.

Modules

One app for the whole line.

Analyses and corrections

Enter the titration in mL or the value itself. Labchemi works out the concentration, checks it against the range and suggests the correction in kg or litres.

Chemical store

Chemical stock with a reorder date. Withdrawals are manual, and the forecast comes from the withdrawals you recorded.

Simulator and Comparator

Record the load from the simulator, measure the coating and see the deviation. 159 aluminium alloys in the simulator.

Assistant

powered by Anthropic

An anodizing specialist that reads your line, stock and loads and prepares the entry. You are the one who saves it.

The panels show the four anodized finishes in order: natural, champagne, bronze and black.

Knowledge and Problems

31 technical articles. 15 defect sheets with diagnosis.

From symptom to tank

SymptomCommon causesWhere to look first
BurningHigh current density, poor rack contact, weak agitation.Rectifier and racks
Uneven colourIrregular coating thickness, colouring bath out of range.Colouring bath
Thin or soft coatingHigh bath temperature, dissolved aluminium above the limit.Anodizing bath
White powder after sealingSealing too long or high pH in the sealing tank.Sealing bath

Four example sheets.

The basics behind the tank

  • Tank electricsRectifier, contacts and current distribution.
  • pHWhat it changes in colouring and sealing.
  • Ohm's lawVoltage, current and the resistance of the growing coating.
  • EtchingThe satin finish before anodizing.
  • BrighteningChemical brightening and its limit.
  • ElectrocolouringColour from metal deposited at the bottom of the pores.
See Knowledge and Problems

Questions

Frequently asked questions

Does Labchemi replace bath titration?

No. You keep titrating. Labchemi converts the reading into concentration, compares it with the tank range and calculates how much to add.

How is the anodic coating thickness calculated?

By a theoretical model of the cell that takes current density, time, temperature, acid concentration, dissolved aluminium and the alloy into account. Real measurements never change the calculation: they are compared with it.

Does it work for hard anodizing and decorative anodizing?

Yes. There are decorative, architectural and hard-coat line templates, and the simulator covers applications from 8 to 60 µm.

Do I need to install anything?

No. Labchemi runs in the browser, on a computer, tablet or phone.

Does the AI change my data on its own?

No. The assistant only prepares the entry. It is saved when a person checks and confirms it on screen.

Which languages is Labchemi available in?

Portuguese, English, Spanish, German, Italian, French and Hebrew, in every screen and in all the technical content.

Account

Start with your line.

Each anodizer works in its own account. What belongs to your company is not shown to anyone else.

  • Runs in the browser. Nothing to install.
  • Three access levels: administrator, supervisor and user.
  • Every entry keeps who made it, when and through which path.
  • Full export and account deletion whenever you want.