Analysis and corrections
From the burette to the correction, no spreadsheet.
Log the titration reading as it comes off the bench. Labchemi works out the concentration, puts it next to the bath range and shows how much to add, dilute or dump.

What it does
Enter the titration in mL or the value itself. Labchemi works out the concentration, checks it against the range and suggests the correction in kg or litres.
01 / 04
Titration in mL or a direct value
Ready methods for sulphuric anodizing, cleaning and alkaline etch, tin and nickel, plus the factor from your data sheet. The raw reading and the calculated value are saved together.
02 / 04
Status against the range
Out of range is critical; within 10 % of the edge, warning. Each parameter has its own range and a record of where it came from.
03 / 04
Suggested correction, with the maths shown
Litres of 98 % sulphuric acid, kg of caustic flakes, dilution or partial dump. The decision to add stays with the person in charge.
04 / 04
Schedule and trend
Each parameter has its own analysis frequency. From the last eight analyses, the sheet shows the trend and in how many days the limit will be crossed.
On the line, day to day
- Pick the tank and the analysis method.
- Type in the burette readings, or the final value if the analysis came from the lab.
- Check the status of each parameter and the suggested correction.
- Save. The analysis goes into the history, the trend and the CSV export.
Sulphuric anodizing bath, 3,000 L
- Sample
- 10 mL · NaOH 1.0 N · with KF
- Reading B (free acid)
- 29.0 mL
- Free H₂SO₄
- 29.0 × 4.904 = 142.2 g/L
- Bath range
- 150–200 g/L · target 180
- Status
- Below range
- Suggested correction
- ≈ 63 L of 98 % H₂SO₄
Correction maths: (180 − 142.2) × 3,000 ÷ 1,803. Add slowly, with agitation, and analyse the bath again.
Questions
Analysis and corrections
Do I have to use the Labchemi analysis methods?
No. Besides the ready methods there is a factor method (value = mL × the factor on your data sheet), and you can log the final value when the analysis was done elsewhere.
Does Labchemi take the product out of stock when it suggests a correction?
No. The suggestion is advisory; the stock issue is logged by hand in the Stock area by whoever made the addition. That way stock only records what actually left.
Where do the bath ranges come from?
The catalogue has starting ranges for each bath type. Each line adjusts them to its product data sheets and the standards it follows, and the source of each limit is recorded.
Platform
Other areas of Labchemi

Chemical store
The right chemical, before it runs out.

Knowledge and problems
From the defect on the part to the cause in the bath.

Simulator and Comparator
The coating you will get, before the rectifier is on.

Assistant
An anodizing specialist that knows your line.
Start with your line.
Create your company account, register your baths and log the first analysis. In the browser, nothing to install.